USB Converter UPort 1130

1 port RS-422/485 serial to USB 2.0 converter with data recovery and fixed COM port feature

$118.81
9% Tax included Shipping calculated at checkout.

- Automatic Recovery Data Communication (ARDC)
- Additional I/O or IRQ not required
- Compatible with USB 2.0
- 15 KV ESD protection for serial port
- Full modem status LEDs
- Full-speed USB operation at up to 12 Mbps
- Serial transmission speed up to 921.6 kbps for fast data transmission
- 64-byte FIFO and built-in hardware and software flow control
- Support for RS-422, 2-wire RS-485, and 4-wire RS-485 
- Full range of drivers supported for Windows, Linux, macOS, Andriod

 

Moxa UPort 1130 USB to serial converter provides a reliable and easy way to add serial COM port to your laptop/computer. UPort 1130 adds one RS-422, 2 wire RS-485, or 4 wire RS-485 port to your computer. Simply install the drivers, connect the UPort to your computer, plug in your serial devices, and you’re ready to go. Programming is not required, and you do not need to worry about IRQs, configuring a board, power requirements, or connection schemes. 

Moxa Uport series is compatible with legacy and latest windows operating systems, macOS, Linux and Android platforms. Making it a very useful tool for engineers who need to connect different serial devices in the field or separate interface converters for devices without a standard COM port or DB9 connector. It is a useful and reliable tool for engineers to connect different serial devices in the field or separate interface converters for devices without a standard COM port or DB9 connector.  

 

Prevent Data Loss - Automatic Recovery Data Communication (ARDC) Feature

Moxa's Uport ARDC feature makes it easier to recover data transmission, even if the  cable is accidentally unplugged. This means that you do not need to worry about reconfiguring complex  settings to ensure smooth data  transmission. If the USB cable is accidentally unplugged, reconnect back to the same port. Moxa Uport 1130 will automatically reconnect with the host and continue your data transfer process. This eliminates the need for reconfiguration and lowers probability of data loss.

Easy Installation Process

Installation of Moxa Uport 1130 for serial to USB connectivity is simple. First, install the driver; then, plug the converter into a USB port. When Uport 1130 converter is connected, Windows will load the correct drivers for the converter and the new COM port. For best results, TNS recommends installing the driver before plugging the converter into USB port. After the driver and hardware have been successfully installed, the new COM port will have a COM number and  can be accessed and controlled just like your PC’s built-in COM ports. If you need to change the baudrate, parity, or other COM port settings, you may use your serial communication application to make those changes.

Advanced Functions: Fixed-base COM Mode

Moxa’s UPort 1100 series provides the unique Fixed-base COM function that allows users to set a specific beginning COM port number. Regardless of which UPort is plugged into the host, the COM port numbers for the 
UPort’s serial ports will be numbered sequentially—starting with the initial COM port number. 

Serial Signals

RS-422 | Tx+, Tx-, Rx+, Rx-, GND

RS-485 (4 wire) | Tx+, Tx-, Rx+, Rx-, GND

RS-485 (2 wire) | Data+, Data-, GND

USB to serial RS422/485 Converter Moxa UPort 1130
Moxa

USB Converter UPort 1130

$118.81

- Automatic Recovery Data Communication (ARDC)
- Additional I/O or IRQ not required
- Compatible with USB 2.0
- 15 KV ESD protection for serial port
- Full modem status LEDs
- Full-speed USB operation at up to 12 Mbps
- Serial transmission speed up to 921.6 kbps for fast data transmission
- 64-byte FIFO and built-in hardware and software flow control
- Support for RS-422, 2-wire RS-485, and 4-wire RS-485 
- Full range of drivers supported for Windows, Linux, macOS, Andriod

 

Moxa UPort 1130 USB to serial converter provides a reliable and easy way to add serial COM port to your laptop/computer. UPort 1130 adds one RS-422, 2 wire RS-485, or 4 wire RS-485 port to your computer. Simply install the drivers, connect the UPort to your computer, plug in your serial devices, and you’re ready to go. Programming is not required, and you do not need to worry about IRQs, configuring a board, power requirements, or connection schemes. 

Moxa Uport series is compatible with legacy and latest windows operating systems, macOS, Linux and Android platforms. Making it a very useful tool for engineers who need to connect different serial devices in the field or separate interface converters for devices without a standard COM port or DB9 connector. It is a useful and reliable tool for engineers to connect different serial devices in the field or separate interface converters for devices without a standard COM port or DB9 connector.  

 

Prevent Data Loss - Automatic Recovery Data Communication (ARDC) Feature

Moxa's Uport ARDC feature makes it easier to recover data transmission, even if the  cable is accidentally unplugged. This means that you do not need to worry about reconfiguring complex  settings to ensure smooth data  transmission. If the USB cable is accidentally unplugged, reconnect back to the same port. Moxa Uport 1130 will automatically reconnect with the host and continue your data transfer process. This eliminates the need for reconfiguration and lowers probability of data loss.

Easy Installation Process

Installation of Moxa Uport 1130 for serial to USB connectivity is simple. First, install the driver; then, plug the converter into a USB port. When Uport 1130 converter is connected, Windows will load the correct drivers for the converter and the new COM port. For best results, TNS recommends installing the driver before plugging the converter into USB port. After the driver and hardware have been successfully installed, the new COM port will have a COM number and  can be accessed and controlled just like your PC’s built-in COM ports. If you need to change the baudrate, parity, or other COM port settings, you may use your serial communication application to make those changes.

Advanced Functions: Fixed-base COM Mode

Moxa’s UPort 1100 series provides the unique Fixed-base COM function that allows users to set a specific beginning COM port number. Regardless of which UPort is plugged into the host, the COM port numbers for the 
UPort’s serial ports will be numbered sequentially—starting with the initial COM port number. 

Serial Signals

RS-422 | Tx+, Tx-, Rx+, Rx-, GND

RS-485 (4 wire) | Tx+, Tx-, Rx+, Rx-, GND

RS-485 (2 wire) | Data+, Data-, GND

View product