- Supports Auto Device Routing for easy configuration
- Supports route by TCP port or IP address for flexible deployment
- Connects up to 32 Modbus TCP servers
- Connects up to 31 Modbus RTU/ASCII slaves
- Accessed by up to 32 Modbus TCP clients (retains 32 Modbus requests for each Master)
- Supports Modbus serial master to Modbus serial slave communications
- Built-in Ethernet cascading for easy wiring
- 10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC/ST connector)
- Emergency request tunnels ensure QoS control
- Embedded Modbus traffic monitoring for easy troubleshooting
- Serial port with 2 kV isolation protection (for “-I” models)
- Wide temperature models -40 to 75C available
- Supports redundant dual DC power inputs and 1 relay output
Moxa MGate MB3170 advanced Modbus gateways provide both serial-to-Ethernet communication and serial (master) to serial (slave) communications. In addition, the Mgate MB3170 gateways support simultaneously connecting serial and Ethernet masters with serial Modbus devices. MGate MB3170 can be accessed by up to 32 TCP master/clients or connect to up to 32 TCP slave/servers. Routing through the serial ports can be controlled by IP address, TCP port number, or ID mapping. A featured priority control function allows urgent commands to obtain an immediate response. All models are rugged, DIN-rail mountable, and offer optional built-in optical isolation for serial signals.
Optical Fiber for Ethernet Communication
MGate MB3170 Series has 100BaseFX fiber models that support transmission distances up to 4 km for multi-mode models, and up to 40 km for single-mode models. Optical fiber is well-suited for industrial applications because it is immune to electromagnetic noise and interference. For environments that experience high ground loop voltages, fiber provides the best isolation protection, and because there is no danger of sparking, optical fiber is safer than copper wire to use in hazardous environments.
Auto-Device Routing for Easy Configuration
Moxa’s Auto-Device Routing function helps eliminate many of the problems and inconveniences encountered by engineers who need to configure large numbers of Modbus devices. A single mouse click is all that’s required to set up a slave ID routing table and configure Modbus gateways to automatically detect Modbus requests from a supervisory control and data acquisition (SCADA) system. By removing the need to manually create the slave ID routing table, the Auto-Device Routing function saves engineers significant time and cost.
Priority Control for Urgent Commands
As Modbus networks increase in size and complexity, the lag time between commands and responses becomes a major concern. Advanced models of the MB3000 Series provide a priority control function for urgent commands, allowing users to force certain commands to get an immediate response. Depending on your system’s requirements, different methods are available to define which commands receive priority.
-
Device InterfaceEthernet, Serial RS232, Serial RS422/485
-
Serial Port Qty1
-
ProtocolsModbus RTU/ASCII, Modbus TCP
Delivery | Can I select a specific time for delivery?
Delivery | Can I select a specific time for delivery?
We are unable to allocate a specific time for delivery. You may let us know your preferred timing and we will try our best to meet your request if possible.
Delivery | Do you have self collection option for urgent request?
Delivery | Do you have self collection option for urgent request?
Yes, for urgent purchases, please contact TNS before placing your order
Delivery | Do you provide International Shipping?
Delivery | Do you provide International Shipping?
Yes, TNS offers international shipping out of Singapore. Our delivery partners are Fedex and DHL. Product prices quoted on our website is in Singapore currency by default.
Delivery | Is there free delivery service?
Delivery | Is there free delivery service?
Enjoy free local delivery service for online order over S$80. Free delivery service is within Singapore mainland (excluding Jurong Island, shipyards and restricted locations).
Purchase | Can I use my nickname or alias when placing my order?
Purchase | Can I use my nickname or alias when placing my order?
To ensure the safe delivery of your order, it is recommended to indicate your full name that matches your valid identification document (ID).
Purchase | What is the minimum order?
Purchase | What is the minimum order?
Unless specified, there is no minimum order.
Purchase | What payment methods do you accept?
Purchase | What payment methods do you accept?
TNS accepts payment via credit card, paynow transfer, cash and funds wired to our bank.
Support | Do I need to register for product warranty?
Support | Do I need to register for product warranty?
No registration is necessary. Your product is registered at the time of purchase.
Support | How do I configure/use/troubleshoot Moxa & Axiomtek products?
Support | How do I configure/use/troubleshoot Moxa & Axiomtek products?
TNS offers advice on product configuration and technical support. Our support hotline +65-67476740 is open from 9am to 5.30pm on weekdays. You can also email your questions to us.