CANopen/J1939 Gateway Mgate 5121

1 port CANopen/J1939 to Modbus TCP gateway with enhanced security features

$0.00
9% Tax included Shipping calculated at checkout.

- Simultaneous protocol conversions from CANopen and J1939 to Modbus TCP and SNMP
- Supports Modbus TCP server and SNMP agent
- Supports CANopen master and J1939
- Flexible deployment with Ethernet cascading and dual subnet
- Embedded traffic monitoring/diagnostic information for easy troubleshooting
- Easy device configuration via a web-based console
- microSD card for configuration backup/duplication
- Supports dual redundant DC power inputs and 1 relay output
- CAN port with 2-kV isolation protection
- (optional) -40 to 75°C wide operating temperature models available
- Developed according to IEC 62443-4-2 with Secure Boot

 

Moxa MGate 5121 is an industrial Ethernet gateway to convert CANopen or J1939 to Modbus TCP network communications. To integrate existing CANopen or J1939 devices onto a Modbus TCP network, use the MGate 5121 as a CANopen or J1939 master to collect data and exchange data with the Modbus TCP host. All models are protected by a rugged and compact metal housing and are DIN-rail mountable. The rugged design is suitable for industrial applications such as factory automation and other process automation industries.

 

Easy Configuration

Moxa MGate 5121 gateways are bundled with a web console to make configuration easy without having to install an extra utility. In addition, HTTPS encryption of communication ensures higher network security. In most data-acquisition applications, configuration of CANopen devices can be time-consuming and increase costs. MGate 5121 gateways provide EDS file import function and user can auto scan the CANopen devices to help complete the settings quickly. The MGate gateways provide software-configurable termination resistor settings for CANbus to reduce efforts by eliminating the need to open the chassis.

 

Easy Troubleshooting

MGate 5121 gateways provide a variety of maintenance functions to reduce troubleshooting time and cost, including LED indicators, protocol diagnostics, traffic monitor and tag view. These tools help you capture and check data to easily identify the root cause of issues, especially during the installation stage. The MGate gateways also come with status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a CAN device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. The fault protection function executes actions pre-defined by the user when a host gets disconnected to prevent the end devices from going offline for long periods of time.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
CANopen & J1939 Gateway Moxa Mgate 5121
Moxa

CANopen/J1939 Gateway Mgate 5121

$0.00

- Simultaneous protocol conversions from CANopen and J1939 to Modbus TCP and SNMP
- Supports Modbus TCP server and SNMP agent
- Supports CANopen master and J1939
- Flexible deployment with Ethernet cascading and dual subnet
- Embedded traffic monitoring/diagnostic information for easy troubleshooting
- Easy device configuration via a web-based console
- microSD card for configuration backup/duplication
- Supports dual redundant DC power inputs and 1 relay output
- CAN port with 2-kV isolation protection
- (optional) -40 to 75°C wide operating temperature models available
- Developed according to IEC 62443-4-2 with Secure Boot

 

Moxa MGate 5121 is an industrial Ethernet gateway to convert CANopen or J1939 to Modbus TCP network communications. To integrate existing CANopen or J1939 devices onto a Modbus TCP network, use the MGate 5121 as a CANopen or J1939 master to collect data and exchange data with the Modbus TCP host. All models are protected by a rugged and compact metal housing and are DIN-rail mountable. The rugged design is suitable for industrial applications such as factory automation and other process automation industries.

 

Easy Configuration

Moxa MGate 5121 gateways are bundled with a web console to make configuration easy without having to install an extra utility. In addition, HTTPS encryption of communication ensures higher network security. In most data-acquisition applications, configuration of CANopen devices can be time-consuming and increase costs. MGate 5121 gateways provide EDS file import function and user can auto scan the CANopen devices to help complete the settings quickly. The MGate gateways provide software-configurable termination resistor settings for CANbus to reduce efforts by eliminating the need to open the chassis.

 

Easy Troubleshooting

MGate 5121 gateways provide a variety of maintenance functions to reduce troubleshooting time and cost, including LED indicators, protocol diagnostics, traffic monitor and tag view. These tools help you capture and check data to easily identify the root cause of issues, especially during the installation stage. The MGate gateways also come with status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a CAN device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. The fault protection function executes actions pre-defined by the user when a host gets disconnected to prevent the end devices from going offline for long periods of time.

View product