Ethernet Remote I/O ioLogik E1213

Ethernet remote I/O with 2 port Ethernet switch, 8 DI, 4 DO, 4 DIOs

$373.87
9% Tax included Shipping calculated at checkout.

- User-definable Modbus TCP Slave addressing
- Supports RESTful API for IIoT applications
- Supports EtherNet/IP Adapter
- 2-port Ethernet switch for daisy-chain topologies
- Saves time and wiring costs with peer-to-peer communications
- Active communication with MX-AOPC UA Server
- Supports SNMP v1/v2c
- Easy mass deployment and configuration with ioSearch utility
- Friendly configuration via web browser
- Simplifies I/O management with MXIO library for Windows or Linux
- Class I Division 2, ATEX Zone 2 certification 
- Wide operating temperature models available for -40 to 75°C (-40 to 167°F) environments

 

Simplify integration of analogue and digital I/O with Moxa ioLogik Ethernet remote I/O solution. Choose from the wide selection of data acquisition modules. Moxa’s Ethernet I/O modules support simple, daisy-chain wiring, and dynamic Modbus addressing for easy integration. Free software utilities are available to enable mass deployment and configuration. With a wide operating temperature design, Moxa Ethernet I/O solutions deliver reliable performance in harsh environments. 

Moxa ioLogik E1200 Series supports the popular OT/IT protocols for retrieving I/O data, making it capable of handling a wide variety of applications. Most IT engineers use SNMP or RESTful API protocols, but OT engineers are more familiar with OT-based protocols, such as Modbus and EtherNet/IP. Moxa's Smart I/O makes it possible for both IT and OT engineers to conveniently retrieve data from the same I/O device. Moxa ioLogik E1200 Series speaks six different protocols, including Modbus TCP, EtherNet/IP, and Moxa AOPC for OT engineers, as well as SNMP, RESTful API, and Moxa MXIO library for IT engineers. ioLogik E1200 retrieves I/O data and converts the data to any of these protocols at the same time, allowing you to get your applications connected easily and effortlessly.

Daisy-Chained Ethernet I/O Connection
This industrial Ethernet remote I/O comes with two switched Ethernet ports to allow for the free flow of information downstream to another local Ethernet device, or upstream to a control server via expandable daisy-chained Ethernet I/O arrays. Applications such as factory automation, security and surveillance systems, and tunneled connections can make use of daisy-chained Ethernet for building multidrop I/O networks over standard Ethernet cables. Many industrial automation users are familiar with multidrop as the configuration most typically used in fieldbus solutions. The daisy-chain capabilities supported by ioLogik Ethernet remote I/O units not only increase the expandability and installation possibilities for your remote I/O applications, but also lower overall costs by reducing the need for separate Ethernet switches. Daisy-chaining devices in this way will also reduce overall labor and cabling expenses.

Save Time and Wiring Costs with Peer-to-Peer Communications
In remote automation applications, the control room and sensors are often far removed, making wiring over long distances a constant challenge. With peer-to-peer networking, users may now map a pair of ioLogik Series modules so that input values will be directly transferred to output channels, greatly simplifying the wiring process and reducing wiring costs.

User-Definable Modbus TCP Addressing for Painless Upgrading of Existing Systems
For Modbus devices that are controlled and detected by fixed addresses, users need to spend a vast amount of time researching and verifying initial configurations. Users need to locate each device’s networking details, such as I/O channels or vendor-defined addresses, to enable the initial or start address of a SCADA system or PLC. Devices that support user-definable Modbus TCP addressing offer greater flexibility and easier setup. Instead of worrying about individual devices, users simply configure the function and address map to fit their needs.

Push Technology for Events
When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.

Moxa iologik E1213 Specifications

Input/Output Interface
8 Digital Input Channels + 4 Digital Output Channels + 8 Configurable DIO Channels (by jumper)
Isolation: 3k VDC or 2k Vrms
Buttons: Reset button

Digital Inputs
Connector: Screw-fastened Euroblock terminal
Sensor Type: Dry contact, Wet contact (NPN or PNP)
I/O Mode: DI or event counter
Dry Contact: On: short to GND | Off: open
Wet Contact (DI to COM): On: 10 to 30 VDC | Off: 0 to 3 VDC
Counter Frequency: 250 Hz
Digital Filtering Time Interval: Software configurable
Points per COM: 8 channels

Digital Outputs
Connector: Screw-fastened Euroblock terminal
I/O Type: Sink
I/O Mode: DO or pulse output
Current Rating: 200 mA per channel
Pulse Output Frequency: 500 Hz (max.)
Over-Current Protection: 2.6 A per channel @ 25°C
Over-Temperature Shutdown: 175°C (typical), 150°C (min.)
Over-Voltage Protection: 35 VDC

Power Requirements
Power Consumption: 130 mA @ 24 VDC

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
moxa iologik-e1212-right
Moxa

Ethernet Remote I/O ioLogik E1213

$373.87

- User-definable Modbus TCP Slave addressing
- Supports RESTful API for IIoT applications
- Supports EtherNet/IP Adapter
- 2-port Ethernet switch for daisy-chain topologies
- Saves time and wiring costs with peer-to-peer communications
- Active communication with MX-AOPC UA Server
- Supports SNMP v1/v2c
- Easy mass deployment and configuration with ioSearch utility
- Friendly configuration via web browser
- Simplifies I/O management with MXIO library for Windows or Linux
- Class I Division 2, ATEX Zone 2 certification 
- Wide operating temperature models available for -40 to 75°C (-40 to 167°F) environments

 

Simplify integration of analogue and digital I/O with Moxa ioLogik Ethernet remote I/O solution. Choose from the wide selection of data acquisition modules. Moxa’s Ethernet I/O modules support simple, daisy-chain wiring, and dynamic Modbus addressing for easy integration. Free software utilities are available to enable mass deployment and configuration. With a wide operating temperature design, Moxa Ethernet I/O solutions deliver reliable performance in harsh environments. 

Moxa ioLogik E1200 Series supports the popular OT/IT protocols for retrieving I/O data, making it capable of handling a wide variety of applications. Most IT engineers use SNMP or RESTful API protocols, but OT engineers are more familiar with OT-based protocols, such as Modbus and EtherNet/IP. Moxa's Smart I/O makes it possible for both IT and OT engineers to conveniently retrieve data from the same I/O device. Moxa ioLogik E1200 Series speaks six different protocols, including Modbus TCP, EtherNet/IP, and Moxa AOPC for OT engineers, as well as SNMP, RESTful API, and Moxa MXIO library for IT engineers. ioLogik E1200 retrieves I/O data and converts the data to any of these protocols at the same time, allowing you to get your applications connected easily and effortlessly.

Daisy-Chained Ethernet I/O Connection
This industrial Ethernet remote I/O comes with two switched Ethernet ports to allow for the free flow of information downstream to another local Ethernet device, or upstream to a control server via expandable daisy-chained Ethernet I/O arrays. Applications such as factory automation, security and surveillance systems, and tunneled connections can make use of daisy-chained Ethernet for building multidrop I/O networks over standard Ethernet cables. Many industrial automation users are familiar with multidrop as the configuration most typically used in fieldbus solutions. The daisy-chain capabilities supported by ioLogik Ethernet remote I/O units not only increase the expandability and installation possibilities for your remote I/O applications, but also lower overall costs by reducing the need for separate Ethernet switches. Daisy-chaining devices in this way will also reduce overall labor and cabling expenses.

Save Time and Wiring Costs with Peer-to-Peer Communications
In remote automation applications, the control room and sensors are often far removed, making wiring over long distances a constant challenge. With peer-to-peer networking, users may now map a pair of ioLogik Series modules so that input values will be directly transferred to output channels, greatly simplifying the wiring process and reducing wiring costs.

User-Definable Modbus TCP Addressing for Painless Upgrading of Existing Systems
For Modbus devices that are controlled and detected by fixed addresses, users need to spend a vast amount of time researching and verifying initial configurations. Users need to locate each device’s networking details, such as I/O channels or vendor-defined addresses, to enable the initial or start address of a SCADA system or PLC. Devices that support user-definable Modbus TCP addressing offer greater flexibility and easier setup. Instead of worrying about individual devices, users simply configure the function and address map to fit their needs.

Push Technology for Events
When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.

Moxa iologik E1213 Specifications

Input/Output Interface
8 Digital Input Channels + 4 Digital Output Channels + 8 Configurable DIO Channels (by jumper)
Isolation: 3k VDC or 2k Vrms
Buttons: Reset button

Digital Inputs
Connector: Screw-fastened Euroblock terminal
Sensor Type: Dry contact, Wet contact (NPN or PNP)
I/O Mode: DI or event counter
Dry Contact: On: short to GND | Off: open
Wet Contact (DI to COM): On: 10 to 30 VDC | Off: 0 to 3 VDC
Counter Frequency: 250 Hz
Digital Filtering Time Interval: Software configurable
Points per COM: 8 channels

Digital Outputs
Connector: Screw-fastened Euroblock terminal
I/O Type: Sink
I/O Mode: DO or pulse output
Current Rating: 200 mA per channel
Pulse Output Frequency: 500 Hz (max.)
Over-Current Protection: 2.6 A per channel @ 25°C
Over-Temperature Shutdown: 175°C (typical), 150°C (min.)
Over-Voltage Protection: 35 VDC

Power Requirements
Power Consumption: 130 mA @ 24 VDC

View product